Nitrogen
-
GC1 Series - Nitrogen Mass Flow Controller - Aluminum, Low Flow, With or Without LCD Readout, 1/4 Inch Compression Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Controllers are compact, self contained and easy to read. The rugged design and instrumentation grade accuracy provide versatile and economical means of flow control ideal in laboratory and industrial settings. The built-in electromagnetic valve allows the flow to be set to any desired flow rate within range of a particular model. Set points may be controlled either locally or remotely.
Available in flow ranges from 10 mL/min to 1000L/min relative to Nitrogen. Accuracy +/-1% full scale for models up to 100 Liters per minute. -
GC5 Series - Nitrogen Mass Flow Controller - Aluminum, High Flow, With or Without LCD Readout, 3/8 Inch Compression Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Controllers are compact, self contained and easy to read. The rugged design and instrumentation grade accuracy provide versatile and economical means of flow control ideal in laboratory and industrial settings. The built-in electromagnetic valve allows the flow to be set to any desired flow rate within range of a particular model. Set points may be controlled either locally or remotely.
Available in flow ranges from 10 mL/min to 1000L/min relative to Nitrogen. Accuracy +/-1% full scale for models up to 100 Liters per minute. -
GC3 Series - Nitrogen Mass Flow Controller - Aluminum, Medium Flow, With or Without LCD Readout, 1/4 Inch Compression Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Controllers are compact, self contained and easy to read. The rugged design and instrumentation grade accuracy provide versatile and economical means of flow control ideal in laboratory and industrial settings. The built-in electromagnetic valve allows the flow to be set to any desired flow rate within range of a particular model. Set points may be controlled either locally or remotely.
Available in flow ranges from 10 mL/min to 1000L/min relative to Nitrogen. Accuracy +/-1% full scale for models up to 100 Liters per minute. -
GC3 Series - Nitrogen Mass Flow Controller - Stainless Steel, Medium Flow, With or Without LCD Readout, 1/4 Inch Compression Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Controllers are compact, self contained and easy to read. The rugged design and instrumentation grade accuracy provide versatile and economical means of flow control ideal in laboratory and industrial settings. The built-in electromagnetic valve allows the flow to be set to any desired flow rate within range of a particular model. Set points may be controlled either locally or remotely.
Available in flow ranges from 10 mL/min to 1000L/min relative to Nitrogen. Accuracy +/-1% full scale for models up to 100 Liters per minute. -
GC1 Series - Nitrogen Mass Flow Controller - Stainless Steel, Low Flow, With or Without LCD Readout, 1/4 Inch Compression Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Controllers are compact, self contained and easy to read. The rugged design and instrumentation grade accuracy provide versatile and economical means of flow control ideal in laboratory and industrial settings. The built-in electromagnetic valve allows the flow to be set to any desired flow rate within range of a particular model. Set points may be controlled either locally or remotely.
Available in flow ranges from 10 mL/min to 1000L/min relative to Nitrogen. Accuracy +/-1% full scale for models up to 100 Liters per minute. -
GC5 Series - Nitrogen Mass Flow Controller - Stainless Steel, High Flow, With or Without LCD Readout, 3/8 Inch Compression Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Meters are compact and easy to read. Used in laboratory and industrial settings to measure and read the flow rates of gases. The rugged designed coupled with instrumentation grade accuracy provides versatile and economical means of flow measurement. Aluminum models with readout options of either engineering units (standard) or 0 to 100 percent displays are available.
The mechanical layout of the design includes an LCD readout built into the top of the transducer. This readout module is tiltable over 90 degrees to provide optimal reading comfort. It is connected to the transducer by a standard modular plug, and is also readily removable for remote reading installations.
-
GC4 Series - Nitrogen Mass Flow Controller - Aluminum, Medium Flow, With or Without LCD Readout, 3/8 Inch Compression Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Controllers are compact, self contained and easy to read. The rugged design and instrumentation grade accuracy provide versatile and economical means of flow control ideal in laboratory and industrial settings. The built-in electromagnetic valve allows the flow to be set to any desired flow rate within range of a particular model. Set points may be controlled either locally or remotely.
Available in flow ranges from 10 mL/min to 1000L/min relative to Nitrogen. Accuracy +/-1% full scale for models up to 100 Liters per minute. -
GC6 Series - Nitrogen Mass Flow Controller - Aluminum, High Flow, With or Without LCD Readout, 1/2 Inch Compression Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Controllers are compact, self contained and easy to read. The rugged design and instrumentation grade accuracy provide versatile and economical means of flow control ideal in laboratory and industrial settings. The built-in electromagnetic valve allows the flow to be set to any desired flow rate within range of a particular model. Set points may be controlled either locally or remotely.
Available in flow ranges from 10 mL/min to 1000L/min relative to Nitrogen. Accuracy +/-1% full scale for models up to 100 Liters per minute. -
GC4 Series - Nitrogen Mass Flow Controller - Stainless Steel, Medium Flow, With or Without LCD Readout, 3/8 Inch Compression Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Controllers are compact, self contained and easy to read. The rugged design and instrumentation grade accuracy provide versatile and economical means of flow control ideal in laboratory and industrial settings. The built-in electromagnetic valve allows the flow to be set to any desired flow rate within range of a particular model. Set points may be controlled either locally or remotely.
Available in flow ranges from 10 mL/min to 1000L/min relative to Nitrogen. Accuracy +/-1% full scale for models up to 100 Liters per minute. -
GC6 Series - Nitrogen Mass Flow Controller - Stainless Steel, High Flow, With or Without LCD Readout, 1/2 Inch Compression Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Meters are compact and easy to read. Used in laboratory and industrial settings to measure and read the flow rates of gases. The rugged designed coupled with instrumentation grade accuracy provides versatile and economical means of flow measurement. Aluminum models with readout options of either engineering units (standard) or 0 to 100 percent displays are available.
The mechanical layout of the design includes an LCD readout built into the top of the transducer. This readout module is tiltable over 90 degrees to provide optimal reading comfort. It is connected to the transducer by a standard modular plug, and is also readily removable for remote reading installations.
-
GC7 Series - Nitrogen Mass Flow Controller - Aluminum, High Flow, With or Without LCD Readout, 3/4 Inch FNPT Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Controllers are compact, self contained and easy to read. The rugged design and instrumentation grade accuracy provide versatile and economical means of flow control ideal in laboratory and industrial settings. The built-in electromagnetic valve allows the flow to be set to any desired flow rate within range of a particular model. Set points may be controlled either locally or remotely.
Available in flow ranges from 10 mL/min to 1000L/min relative to Nitrogen. Accuracy +/-1% full scale for models up to 100 Liters per minute. -
GC7 Series - Nitrogen Mass Flow Controller - Stainless Steel, High Flow, With or Without LCD Readout, 3/4 Inch FNPT Fittings, 0-5VDC Analog Input/Output
Dakota's Mass Flow Meters are compact and easy to read. Used in laboratory and industrial settings to measure and read the flow rates of gases. The rugged designed coupled with instrumentation grade accuracy provides versatile and economical means of flow measurement. Aluminum models with readout options of either engineering units (standard) or 0 to 100 percent displays are available.
The mechanical layout of the design includes an LCD readout built into the top of the transducer. This readout module is tiltable over 90 degrees to provide optimal reading comfort. It is connected to the transducer by a standard modular plug, and is also readily removable for remote reading installations.